PURPOSE
There are observable disadvantages to using Collodion. Collodion causes skin breakdown. Some patients are ALLERGIC to collodion. Collodion is flammable and has a strong and unpleasant odor, requiring adequate ventilation. Electrodes attached to collodion are removed with acetone, which can irritate the skin, especially when used on babies and patients in the ICU. Collodion is difficult to remove, sometimes leaving residue on the patient‘s scalp, making them uncomfortable. The purpose of this technique is to provide an alternative to doctors and techs who DO NOT want to use Collodion. It will minimize patient discomfort and still provide a high-quality EEG recording.
RESULTS/CONCLUSION: The electrodes remain secure in patients with severe seizures and behavioral disorders. They have low impedance, and no repairs are needed during long-term EEG/video monitoring. Electrodes are easily removed with water. Patient feedback is positive, and skin breakdown is avoided. Collodion IS NOT NECESSARY for long-term EEG/video monitoring. This alternative produces a high-quality recording and benefits the patient, especially those ALLERGIC to collodion. I have used this technique since 1996 on HUNDREDS of patients and have seen consistent results.